·Spectronic Air Circuit Breakers
·MPACT Air Circuit Breakers
·UNEPACT Air Circuit Breakers
Spectronic Air Circuit Breakers
- New Generation ACB's with the latest design of Unelec, France.
- Circuit Breaker as per IEC60947-2/IS13947-2.
- Microprocessor based releases.
- Stored Energy Drive Mechanism even for manually operated breakers.
- Rating 800A-6400A.
- 3P/4P,Manual and Electrical versions.
- Icu=Icw=55 kA to 120 kA for various ratings.
- Ics=55 kA to 100 kA for various ratings.
- Max Nominal Voltage=Insulation Voltage=1000V.
- Unique feature of Electrical life=Mechanical life ensures long life and trouble free operation.
- Total discrimination guranteed.
- Two types of Microprocessor based releases:
| - |
RMS7. |
| - |
RMS9 with communication interface. |
- Facility to close manually operated breakers from remote with closing coil.
- Different termination options provide flexibility.
- Wide range of available accessories.
- Safety Shutters as an inbuilt feature.
- Distinct fault signalling with microprocessor based releases.
Configure your Spectronic ACB here Top | 
| MPACT Air Circuit Breakers
- Confirms to IS 13947-2.
- 800A to 4000 A in 3P Version.
- 800 A to 2500A in 4P Version.
- Icu=Ics=Icw=50 kA.
- Unique Cassette design ensures 100% guarantee of the short circuit performance, since the proving tests have been conducted on ACB in the cassette.
- Three distinct positions-Service, Test & Isolated.
- Line Load interchangability.
- Manual and Electrical versions available.
- Static trip releases for accurate & flexible operation.
- Safety features:
| - |
Safety shutters (lockable). |
| - |
Door interlocks. |
| - |
Access flap (for accessing operating mechanism) locking facility. |
| - |
Stopper on guide rails to prevent accidental falling when breaker is withdrawn. |
| - |
One rating ACB can not be inserted into the cassette of another rating of ACB. |
| - |
ACB position indicator. |
- Wide range of accessories available.
Top | 
| UNEPACT Air Circuit Breakers
- Available from 800A to 2500A in two basic frame sizes.
- Compact ACB for building switchboards with 500mm depth panels.
- Fixed, Draw out, Manual and Electrical versions.
- Uniform Door cutout.
- Breaking capacity of 50kA @415V AC.
- 3 pole & 4 Pole versions.
- Static trip release type RW2.
- Height & Depth same for all ratings (width varies for different current ratings).
- Draw out breakers have safety shutters with padlocking facility.
- Trip free mechanism with mechanical ON/OFF indicators.
- Wide range of accessories available.
Top | 
|
|
|